Is the Fujitsu XLTH 15k suitable as primary heat in a cold winter?+
Fujitsu's floor is -15°F, and NEEP certifies 18,000 BTU at 47°F and 21,000 BTU at 5°F with a COP of 2.1. Output at 5°F is 1.4 times the 15,000 BTU label, which is solid for a single room or open space. It is a good fit for a cold-climate main living area.
How does it compare to the Mitsubishi FX15?+
The XLTH 15k is rated 27.5 SEER2 and 12.7 HSPF2 at about $3,274, against the FX15's 25.9 and 11 at about $3,786. The Mitsubishi certifies 22,200 BTU at 5°F against Fujitsu's 21,000 and goes to -22°F. The Fujitsu is cheaper and more efficient on paper; the Mitsubishi has more cold-weather margin.
What does the Fujitsu warranty require?+
The base term is 5 years parts and 7 years compressor. It extends to 10 years if you register within 60 days, and to 12 years with an install by a Fujitsu Elite contractor.
What circuit and lineset does it need?+
Both units run on a 208/230V, 20A circuit, and the lineset is 1/4" x 1/2" with a 98 ft maximum run and 82 ft maximum rise. It uses R-32, an A2L mildly flammable refrigerant, so use a trained installer.
What size room is 15,000 BTU right for?+
It is listed for about 600 sq ft. That suits a large bedroom or a main living space with a reasonably open plan.