Mini-split BTU calculator
Enter the room and get the cooling it needs, then every single-zone mini-split in the catalog that is the right size for it. If heating is the reason you are buying, tick cold winters to sort by what each unit still puts out at 5°F.
About 8,000 BTU of cooling
350 sq ft: 8,000 BTU on the ENERGY STAR chart.
11 of 114 units are the right size.
- Senville LETO 9,000 BTU9,000 BTU · 113% of your load$700 · Single-Zone · 6,500 BTU at 5°F
- LG Standard 9,000 BTU9,000 BTU · 113% of your load$899 · Single-Zone · not on the NEEP list
- LG Mega 9,000 BTU9,000 BTU · 113% of your load$1,143 · Single-Zone · not on the NEEP list
- Gree Livo R-32 9,000 BTU9,000 BTU · 113% of your load$1,321 · Single-Zone · 7,600 BTU at 5°F
- Senville AURA 9,000 BTU (Cold Climate)9,000 BTU · 113% of your load$1,650 · Single-Zone · not on the NEEP list
- LG Art Cool Deluxe LGRED 9,000 BTU9,000 BTU · 113% of your load$2,017 · Single-Zone · 12,000 BTU at 5°F
- Daikin Aurora 9,000 BTU Cold Climate9,000 BTU · 113% of your load$2,155 · Single-Zone · 10,900 BTU at 5°F
- Mitsubishi MSZ-GX09NL Hyper-Heat 9,000 BTU9,000 BTU · 113% of your load$2,570 · Single-Zone · 9,600 BTU at 5°F
- Fujitsu Airstage 9KZAH1 Extra-Low-Temp 9,000 BTU9,000 BTU · 113% of your load$2,789 · Single-Zone · 15,400 BTU at 5°F
- Mitsubishi MSZ-FX09NL Hyper-Heat 9,000 BTU9,000 BTU · 113% of your load$2,930 · Single-Zone · 14,700 BTU at 5°F
- Gree Sapphire R-32 9,000 BTU9,000 BTU · 113% of your load$2,932 · Single-Zone · 11,500 BTU at 5°F
How the number is worked out
The starting point is ENERGY STAR’s room-size chart, which assumes 8-foot ceilings, decent insulation, moderate sun and a temperate climate. Small rooms need more per square foot than big ones: 250 sq ft is 6,000 BTU, 400 sq ft is 9,000. A taller ceiling counts as more floor, because BTUs move air: a 12-foot ceiling makes 400 sq ft count as 600. A sunny room adds 10% and a fully shaded one takes 10% off. Each person beyond two adds 600 BTU, and a kitchen counts as 4,000, the top of its 1,500-4,000 range.
A unit counts as the right size between 80% and 120% of that number. A mini-split slows its compressor down instead of switching off, and that only works when it is not too big: an oversized one blasts the room to temperature, shuts off and leaves it clammy. A slightly small one just runs longer on the hottest days.
This is a cooling estimate. In a cold climate the heating load usually decides the size, and that needs a load calculation for your house at your winter low. The 5°F figures come from the NEEP cold-climate heat pump list; a unit without one has not been listed there. More in the sizing guide and the cold-climate guide.